Analisis E. Coli Pada Air Minum Dalam Kemasan Yang Beredar Di Kota Tasikmalaya

Vita Meylani(1*), Rinaldi Rizal Putra(2)

(1) Prodi. Pendidikan Biologi FKIP Universitas Siliwangi
(2) Prodi. Pendidikan Biologi FKIP Universitas Siliwangi
(*) Corresponding Author

Abstract

Drinking water is the main need of humans as living things. Over time, humans are more practical so that for drinking needs they prefer to use bottled drinking water or refill drinking water. The high demand for bottled water raises the number of drinking water companies that issue bottled drinking water products. However, the quality of bottled water still needs to be assessed because it is not through pasteurization or other processing. So the microbiological content remains to be investigated. This study aimed to determine the bacteriological content in bottled drinking water. This study uses the Most Probable Number (MPN) method to test its bacterial content and gamma ray radiation to test its radiosensitivity. The sample in this study was bottled drinking water of various brands circulating in the City of Tasikmalaya. Based on the research results obtained from 13 samples there is 1 sample containing E. coli which is code B1 with a total bacterial content of 7 cells per 100 ml. So it can be concluded L samples are known to contain E. coli as much as 1.9 x 105 cells per ml.

Keywords

E.coli, MPN, drinking water, Tasikmalaya

Full Text:

PDF

References

Apriliana, Ety., Ramadhian, M. Ricky., & Gapila, Meta. 2014. Bacteriological Quality of Refill Drinking Water at Refill Drinkung Water Depots in Bandar Lampung. JUKE 4 (7): 142-146.

Bambang, Andrian G.,dkk.2014. Analisis Cemaran Bakteri Coliform Dan Identifikasi Eschericia Coli Pada Air Isi Ulang Dari Depot Di Kota Manado. Jurnal Ilmiah Farmasi – UNSRAT. Vol. 3 No.3.https://ejournal.unsrat.ac.id/index.php/pharmacon/article/viewFile/54 50/4957 (diakses tanggal 20 januari 2018)

Keputusan Menteri Kesehatan No. 907/MENKES/SK/VII/2002 Tentang SyaratSyarat dan Pengawasan Kualitas Air Minum PP RI Nomor 82 Tahun 2001 tentang Pengelolaan Kualitas Air dan Pengendalian Pencemaran Air, pasal 8 ayat 1 ditetapkan pengkelasan air sesuai dengan peruntukannya

Kusuma, S. A. F. 2010. Escherichia coli.http://pustaka.unpad.ac.id. Mahdiasanti, I. W. 2010. Uji Bakteriologi Air Minum Isi Ulang di Kota Batu Ditinjau dari Nilai MPN Coliform.Tahun 2010.Jurnal Healthy Science Vol. 1 No. 1: 50-62.

Nuria, Maulita Cut., Rosyid, Abdur., & Sumantri. 2009. Uji Kandungan Bakteri Escherichia coli pada Air Minum Isi Ulang dari Depot Air Minum Isi Ulang si Kabupaten Rembang. Jurnal Ilmu-ilmu Pertanian. 5 (1):27-35.

Pradhika, E. I. 2011. Mikrobiologi Dasar-Metode MPN/ APM-Angka Paling Mungkin Bagian I. http://ekmon-saurusblogspot.com. (diakses tanggal 21 Januari 2017)

Pratama Sekedang, M. Iqbal., Manaf, Zakiah Heryawati., Darmawi., Jamin, Faisal., Abrar, Mahdi., & Razali. 2016. Kontaminasi Bakteri Koliform pada Air Minum Isi Ulang di Desa Ilie Kecamatan Ulee Kareng Kota Banda Aceh. Jurnal Medika Veterinaria. 10(1):70-73.

Prayitno, Agus. 2009. Uji Bakteriologi Air Baku dan Air Siap Konsumsi dari PDAM Surakarta Ditinjau dari Jumlah Bakteri Coliform. Surakarta: Fakultas Keguruan dan Ilmu Pendidikan Universitas Muhammadiyah Surakarta.

Purbowarsito, H. 2011. Uji Bakteriologis Air Sumur di Kecamatan Semampir Surabaya.Skripsi.Tidak dierbitkan.Departemen Biologi Fakultas Sains dan teknologi Universitas Airlangga.

Rahmatullah, A. M. 2013. Studi Karakterisasi Bakteri Escherichia coli di Laboratorium Kesehatan Lumajang.Fakultas Matematika dan Ilmu Pengetahuan Alam Institut Teknologi Sepuluh Nopember.

Soemirat, J. 2004. Kesehatan Lingkungan. Yogyakarta: Gadjah Mada University Press.

Widiyanti dan Ristiati, 2004.Analisis Kualitatif Bakteri Coliform pada Depo Air Minum Isi Ulang di Kota Singaraja Bali.Jurnal Ekologi Kesehatan Vol. 3 No. 1: 64-73.

Article Metrics

Abstract view(s): 4431 time(s)
PDF: 9265 time(s)

Refbacks

  • There are currently no refbacks.