The Coronavirus pandemic or Covid-19 caused by Corona Virus which spread widely in 2020 is very dangerous because it threatens the safety of humanity by means of very fast and easy transmission. One of the most popular prevention efforts is the use of disinfectants to eradicate the corona virus. This study examines an automatic disinfectant mixer which uses a flow meter sensor to measure the flowing solution and the volume of the solution. In addition, this tool also uses a solenoid valve as a cover and automatic valve opening that regulates the running of water. This automatic disinfectant mixer is controlled by the Atmega328P microcontroller at Arduino nano board. In this study the capacity is limited from 1 liter to 5 liters of disinfectant with the composition per liter of disinfectant consisting of 905 mL of water and 95 mL of sodium hypochlorite, while the DC motor will stir for 2 seconds. The results of testing this tool, the flow meter can read the flow and the volume of liquid, but there is an error in the calibration of the flow meter sensor of 0.21 to 1.8%, while in testing the disinfectant volume capacity, this tool can mix disinfectants from water and sodium hypochlorite to a maximum volume capacity of 5 liters, but there is a difference of up to 100-170 mL, between the specified disinfectant capacity and the disinfectant volume contained in the measuring cup.

Keywords

Covid-19, Disinfectant mixer, Flow meter, DC motor

Full Text:

PDF

References

Utami, Sartika P., Mulyadi Ema., Soebandi, Daniyah H. 2016. Perbandingan Daya Antibakteri Desinfektan Instrumen Preparasi Saluran Akar Natrium Hipoklorit 5,25%, Glutaraldehid 2%, dan Desinfektan Berbahan Glutaralhedid terhadap Bacillus subtilis. Universitas Gadjah Mada.

BPOM. 2020. Cegah Corona, Balai POM di Manokwari Lakukan Disinfeksi. https://www.pom.go.id/new/view/more/berita/18162/Cegah-Corona--Balai-POM-di-Manokwari-lakukan-Desinfeksi-.html. (diakses 24 Juni 2020)

Prameswary, Dita A, 2016. Rancang Bangun Alat Pencampur Cat Tembok Otomatis Berbasis Personal Computer (PC). Universitas Airlangga

Fatimah, N., Aisuwarya, R, 2019. Rancang Bangun Sistem Pencampur Minuman Jamu Otomatis Berbasis Mikrokontroler. Universitas Andalas

Triady, Rocky., Triyanto, Dedi., Ilhamsyah. 2014. Prototype Sistem Keran Air Otomatis Berbasis Sensor Flow Meter Pada Gedung Bertingkat. Universitas Tanjungpura.

Andrian, Heri, A. Darmawan. 2016. Arduino Belajar Cepat dan Pemrograman. Bandung : Informatika.

Istiyanto, Jozi Eko. 2014. Pengantar Elektronika dan Implementasi Pendekatan Project Arduino dan Android. Yogyakarta : Andi Offset.

Syahrul., Saputra, Ryan, 2014. Rancang Bangun Pencampur Cat Otomatis Berbasis Mikrokontroler. Universitas Komputer Indonesia.

Steinhauer K. Antimicrobal Efficacy and Systematic Use of Disinfectants. In : Mendez-Vilas A, editor. Current Research, Technology and Education Topics in Applied Microbiology and Microbal Biotechnology. Volume 1. Badajos : Formatex. 2010. 369-376.