Redesign of OrthoLPPDUNS External Fixation for Bone Reconstruction Using the Function Analysis System Technique (FAST) Method
(1) Teknik Industri - Universitas Sebelas Maret Surakarta
(2) Teknik Industri - Universitas Sebelas Maret Surakarta
(3) Teknik Industri - Universitas Sebelas Maret Surakarta
(4) Teknik Industri - Universitas Sebelas Maret Surakarta
(5) Orthopedic Surgery and Traumatology Department, Dr. Soeradji Tirtonegoro Hospital, Klaten
(6) Teknik Industri - Universitas Sebelas Maret Surakarta
(*) Corresponding Author
DOI: https://doi.org/10.23917/jiti.v19i2.10732
Abstract
Taylor Spatial Frame (TSF) better known as an external fixation product from several types of fixation devices in the orthopedic field. The Laboratory of Product Planning and Design has manufactured TSF or called OrthoLPPDUNS external fixations. The OrthoLPPDUNS design found that frame instability forming ring-strut angles caused by strut screw rotations was feeling rough due to backlash. The purpose is how to redesign an OrthoLPPDUNS with a Function Analysis System Technique (FAST). FAST method is applied at each stage of starting from the information stage to the interpretation of the results. The OrthoLPPDUNS design with the joint system uses custom components that cause weakness in frame stability. The use of standard components in joint systems can provide solutions to external fixations, although there are still weaknesses in the ring-strut angle. The OrthoLPPDUNS redesign has a better success rate in terms of stability parameters, allowing more precise bone reconstruction.
Keywords
Full Text:
PDFReferences
Augat, P., Burger, J., Schorlemmer, S., Henke, T., Peraus, M., and Claes, L. (2003). “Shear movement at the fracture site delays healing in a diaphyseal fracture model.” Journal of Orthopaedic Research, Vol. 21, 1011-1017.
Behrens, F. (1989). “General theories and principles of external fixation.” Clinic Orthopaedics J., Vol. 241, 15-23.
Betts, S.C. and Muller, R. (2014). “Mechanical regulation of bone regeneration: theory, models, and experiments.” Frontiers in Endocrinology, Bone Research, 5, 211, 1-14. Accessed April 8, 2020, available from:https://www.ncbi.nlm.nih.gov/pmc/ articles/PMC4261821/pdf/fendo-05-00211.pdf
Birringer, R.P., Ganot, G.S., and James, B.A. (2016). “Failure Analysis of Internal Fixation Medical Devices: Overview and Case Studies.” Journal of Failure Analysis and Prevention, Vol. 16 (5), 849-857.
Bone Fixator. (2018). Taylor Spatial Frame. Accessed April 8, 2020, http://www.bonefixator.com/fracturefixation/taylor_ spatial_frame_1.htm l #figure2.
Dubowy, S.M. and and Nichols, L.R. (2018). Limb Lengthening Surgery: External Fixator. Accessed April 8, 2020, from: https://kidshealth.org/en/parents/limb-lengthen-fixator.html..
Drijber, F.L.I.P., Finlay, J.B., Moroz, T.K. and Rorabeck, C.H. (1990). “Sources of the slippage in the universal joints of the hoffman external fixator.” Med. & Biol. Eng. & Computer J., Vol. 28, 8-14.
Eralp, L., Bilen, F.E., Rozbruch, S.R., Kocaoglu, M., and Hammoudi, A. (2016). “External fixation reconstruction of the residual problems of benign bone tumours.” Strategies in Trauma and Limb Reconstruction, Vol. 11 (1), 37-49.
Evans, J. R. (2014). Quality & Performance Excellence. 7th ed. New York: South-Western College Pubisher.
Heidari, N., Hughes, A. and Atkins, R.M. (2013). “Intra-operative correction of taylor spatial frame without a computer.” J. Orthop Trauma. Vol. 27, e42–e44.
Henderson, R.C., Kemp, G.J., and Greene, W.B. (1992). “Adolescent tibia vara: alternatives for operative treatment.” J. Bone Joint Surg [Am]. Vol. 74A, 342-350.
Henderson, E.R., Feldman, D.S., Craig Lusk, C.L., van Bosse, H.J., Sala, D. and Kummer, F.J. (2008). “Conformational Instability of the Taylor Spatial Frame A Case Report and Biomechanical Study.” J. Pediatric Orthopeadic. Vol. 28, 471-477.
INA. (2008). INA Spherical Plain Bearings. Accessed April 8, 2020, from http://www.ina.de/content.ina.de/en/branches/ industry/solar_power_plants/products_solar/spherical_plain_bbearings/spherical_plain_bearings.jsp.
International Organization for Standardization. (1993). ISO general-purpose metric screw threads - Basic dimensions (ISO Standard No. 724).
Karidis, J.P. (2012). Orthopedic fixation device with zero backlash and adjustable compliance, and process for adjusting same. U.S. Patent 8,202,273 B2.
Keshet, D. and Eidelman, M. (2017). “Clinical utility of the taylor spatial frame for limb deformities.” Orthopedic Research and Reviews, Vol. 9, 51-61.
Nicholas (2010). Lean Production for Competitive Advantage: A Comprehensive Guide to Lean Methodologies and Management Practices, 1st ed. New York: CRC Press.
Norrish, A. (2013). Use of the Taylor Spatial Frame in Trauma. UK: Cambridge University Hospital.
Paley, D. (2002). Principles of Deformity Correction. Berlin Heidelberg: Springer-Verlag.
Paley, D. (2011). “History and science behind the six-axis correction external fixation devices in orthopaedic surgery.” Operative Techniques Orthopaedics, Vol. 21, 125-128.
Putra, I G.M. (2018). “Penyakit Blount - Diagnosis dan Tatalaksana. Fakultas Kedokteran Universitas Udayana, Denpasar, Bali, Indonesia.” Cermin Dunia Kedokteran 261. Vol. 45 (2), 112-114.
Seherr-Thoss, H.C., Schmelz, F. and Aucktor, E. (2006). Universal Joints and Driveshafts: Analysis, Design, Applications. German: Springer.
Sabharwal, S. (2016). Pediatric Lower Limb Deformities: Principles and Techniques of Management. New York: Springer International Publisher.
Shah, S.V., Saha, S.K., and Dutt, J.K. (2012). “Denavit-Hartenberg parameterization of euler angles.” Journal of Computational and Nonlinear Dynamics, Vol. 7 (2), 021006.
SKF. (2011). Catalogue: Spherical Plain Bearings and Rod Ends. Swedia: SKF Group.
Smith & Nephew. (2011). Taylor Spatial Frame External Fixator : Explore the Possibilities. USA: Smith & Nephew Inc.
Solomin, L.N. (2008). The Basic Principles of External Fixation Using the Ilizarov Device. Italia: Springer-Verlag Publisher.
Solomin, L.N. (2012). The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Italia: Springer-Verlag Publisher.
Solon, T. (2010). Backlash vs. Stiffness – What the different is and why you should care. Accessed April 8, 2020, available from: http://www.designworldonline.com/backlash-vs-stiffness-what-the-difference-is-and-why-you-should-care/
Steiner, M., Claes, L., Ignatius, A., Simon, U., and Wehner, T. (2014). “Disadvantages of interfragmentary shear on fracture healing-mechanical insights through numerical simulation.” Journal of Orthopaedic Research, Vol. 32 (7), 865-872.
Tan, B.B., Shanmugam, R., Gunalan, R., Chua, Y.P., Hossain, G., Saw, A. (2014). “A biomechanical comparison between taylor’s spatial frame and ilizarov external fixator.” Malaysia Orthopaedic J. Vol. 8 (2), 35-39.
Taylor, H.S. and J.C. (2000). Six Axis External Fixator Strut. US Patent 6030386.
Ullman, D.G. (1986). Mechanical Design Failure Analysis: with Failure Analysis System Software for the IBM Pc. New York: Marcel Dekker.
Vesali, F., Rezvani, M.A., and Kashfi, M. (2012). “Dynamics of universal joints, its failures and some propositions for practically improving its performance and life expectancy.” Journal of Mechanical Science and Technology. Vol. 26 (8), 2439-2449.
Wijaya, Y.I.D., Susmartini, S. and Herdiman, L. (2019). “Strut and ring connection system design on external fixator based on hexapod to increase bone flexibility reconstruction using finite element analysis.” IOP Conf. Series: Materials Science and Engineering, Vol. 495, 1-11.
Article Metrics
Abstract view(s): 430 time(s)PDF: 456 time(s)
Refbacks
- There are currently no refbacks.